5.8cm thoracic aorta aneurysm

Aortic Aneurysms | Last Active: 3 hours ago | Replies (59)

Comment receiving replies
Profile picture for houston13 @houston13

@rlhix here is one of the devices now approved for all sections of the arch
https://www.goremedical.com/products/thoracic-branch-endoprosthesis

Jump to this post


Replies to "@rlhix here is one of the devices now approved for all sections of the arch https://www.goremedical.com/products/thoracic-branch-endoprosthesis"

@houston13
My arch is fine, but I don't meet those criteria below and was told a quick and hard "No" when I asked Mayo about this due to the remaining 4.6cm native distal ascending aorta. The only mention 77 trials and its still not from the arch to the root as I mentioned. Some people have variations in the arch which are bad just different. Plus it has to meet certain criteria. It seems that the arch has to be close to pristine with a perfect landing zone in the ascending aorta.

INDICATIONS FOR USE: The GORE® TAG® Thoracic Branch Endoprosthesis is indicated for endovascular repair of lesions of the aortic arch and descending thoracic aorta, while maintaining flow into a single aortic arch branch vessel in patients who have: Adequate iliac/femoral access; Proximal Aortic Landing Zones: For Isolated Lesion Patients: Proximal landing zone cannot be aneurysmal, dissected, heavily calcified or heavily thrombosed;

For Dissection Patients: Primary entry tear must be distal to the target branch vessel and the proximal extent of the landing zone must not be dissected; Aortic inner diameter range 16-42 mm; Proximal segment length (length from distal edge of target branch vessel to the midpoint of any proximal branch vessel) of at least 2.0-4.0 cm, depending on Aortic Component selection; Proximal covered length (measured from distal edge of target branch vessel to the distal edge of any proximal branch vessel) of at least 15–36 mm, depending on Aortic Component selection;

For patients with prior ascending aorta or aortic arch repair with surgical graft: at least 2 cm landing zone proximal to the distal anastomosis; Target Branch Vessel Landing Zone: Landing zone cannot be aneurysmal, dissected, heavily thrombosed and severely tortuous (180 degree turn within the treated length); Target branch vessel inner diameter of 6–18 mm, depending on Side Branch Portal diameter selected; Target branch vessel minimum length of 2.5–3.0 cm, depending on Side Branch Portal diameter selected. Distal Landing Zone (Isolated Lesion Patients only): Outer curve length must be ≥ 2 cm proximal to celiac artery; Aortic inner diameter range 16-42 mm; Cannot be aneurysmal, dissected, heavily calcified or heavily thrombosed; Native Aorta or previously placed GORE® TAG® Conformable Thoracic Stent Graft.